MK4duo

New Version 4.3.9

1 vote, average: 5,00 out of 51 vote, average: 5,00 out of 51 vote, average: 5,00 out of 51 vote, average: 5,00 out of 51 vote, average: 5,00 out of 5 (1 votes, average: 5,00 out of 5)
You need to be a registered member to rate this post.
Loading...
  • New graphic for Nextion 4.3, 5.0 or 7.0 Normal and Enanched v1_2_0
  • Add support 6 Hotends, 4 Beds and 4 Chambers
  • Add Support for TMC2130 – TMC2208 – TMC2660 – TMC2160 – TMC5130 – TMC5160 motor driver
  • Add command M228 for setting axis limit min/max
  • Add Prompt support for host
  • Rewrite filament runout
  • Add support for BLTouch V3.0/V3.1
  • Add Prusa MMU2 Support
  • Add support thermocouples for bed and hotend.
  • Add menu axis limit to menu advanced.
  • Add Double-Quad Stepping to command M569 Q and save it into EEPROM.
  • Add Option for Safety Timer in configuration_temperature.h
  • Add G34 and M422 Z Steppers Auto-Alignment (Cartesian and CORE)
  • Add M86 M[min] set safety timer expiration time in minute. M86 M0 will disable safety timer
  • Add M217 – Set Park position and tool change parameters
  • M301 – Set PID parameters P I D and C.
    • H[heaters] 0-5 Hotend, -1 BED, -2 CHAMBER, -3 COOLER
    • T[int] 0-3 For Select Beds or Chambers (default 0)
    • P[float] Kp term, I[float] Ki term, D[float] Kd term
    • With PID_ADD_EXTRUSION_RATE: C[float] Kc term, L[int] LPQ length
  • M303 – PID relay autotune.
    • H[heaters] 0-5 Hotend, -1 BED, -2 CHAMBER, -3 COOLER
    • T[int] 0-3 For Select Beds or Chambers (default 0)
    • S[temperature] sets the target temperature (default target temperature = 150C), C[cycles], U[Apply result],
    • R[Method] 0 = Classic Pid, 1 = Some overshoot, 2 = No Overshoot, 3 = Pessen Pid
  • M305 – Set thermistor and ADC parameters.
    • H[heaters] 0-5 Hotend, -1 BED, -2 CHAMBER, -3 COOLER
    • T[int] 0-3 For Select Beds or Chambers (default 0)
    • A[float] Thermistor resistance at 25°C, B[float] BetaK, C[float] Steinhart-Hart C coefficien, R[float] Pullup resistor value,
    • L[int] ADC low offset correction, O[int] ADC high offset correction, P[int] Sensor Pin
    • Set DHT sensor parameter: D0 P[int] Sensor Pin, S[int] Sensor Type (11, 21, 22).
  • M306 – Set Heaters parameters.
    • H[heaters] 0-5 Hotend, -1 BED, -2 CHAMBER
    • T[int] 0-3 For Select Beds or Chambers (default 0)
    • A[int] Pid Drive Min, B[int] Pid Drive Max, C[int] Pid Max,
    • L[int] Min temperature, O[int] Max temperature, U[bool] Use Pid/bang bang,
    • I[bool] Hardware Inverted, T[bool] Thermal Protection, P[int] Pin
  • G34 I[iterations] [accuracy] A[amplification]
  • Add Game menu
  • Add DHT menu
  • Add DHT disply Dew Point
  • Fix MBL
  • Fix and clear code